Hancock Pulmonic Conduit Model 105 Medtronic, Inc. www.Medtronic.com. The Profile 3D annuloplasty system has a unique asymmetrical 3D remodeling ring design based on the annular geometry of normal human mitral annuli.
Federal law (USA) restricts this device to sale by or on the order of a physician. The Instructions for Use for the modified Mosaic obturators/sizers has been updated to include the new sizing chart (iEOA chart). To address the issue, Medtronic Australasia is recalling resources used to select appropriately sized devices for implantation.
The adverse events potentially associated with the use of prosthetic aortic heart valves include, but are not limited to: angina, cardiac arrhythmia, endocarditis, hemolysis, hemolytic anemia, anticoagulant-related hemorrhage, myocardial infarction, leaflet entrapment (impingement), nonstructural dysfunction, pannus, perivalvular leak, transvalvular regurgitation, structural dysfunction, thrombosis, stroke, thromboembolism. The Mosaic bioprosthesis is an evolution in durability and implantability, based on the proven platform of the Hancock II valve. Mosaic Porcine Bioprosthesis. Surgical valve treatment for mitral and aortic valve disease The Epic Plus Mitral stented tissue valve is indicated for patients requiring replacement of a diseased, damaged, or malfunctioning native mitral heart valve. Aortic and Mitral Valve Surgery - Important Safety Information - Medtronic
Extreme caution must be exercised by the surgeon during surgery to safeguard against undesirable results and postoperative complications.implant should be trimmed (or a shorter implant selected) if it is too long for the vestibule to avoid any contact with sensitive inner ear structures. The Hancock II and Hancock II Ultra are for patients who require replacement of their native or prosthetic aortic and/or mitral valves.
Update my browser now. The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue-valve design expertise is a great option for surgeons seeking exceptional long-term durability, excellent hemodynamics, and a smooth implanting experience.
AMEND Mitral Annuloplasty Ring, All Sizes Valcare Medical LTD., www.valcaremedical.com.
CSF Flow Control Valve, Fixed Pressure Medtronic, Inc., www.medtronic.com. EpiFilm Otologic Lamina is indicated for myringoplastic and tympanoplastic surgical procedures. Home FLEX H/A is a homogenous, nonporous composite of two well-known biomaterials: hydroxylapatite and silicone. 1.5, 3: . It is important to consult the full system manuals for the most updated information.
Module 1: MRI in patients with a prosthetic heart valve, annuloplasty.
Biomaterials, Nasal Packing & Ear Packing PDF Guidelines for Managing Patients with Heart Valve Prostheses - ISMRM Reduced hearing or total deafness is at risk in such cases. Higher-than-expected transvalvular gradients (>25 mmHg) associated with the Mosaic Procine Aortic Bioprosthesis Model 305 have occurred at a rate of 0.33% (3.3 reports per 1000 aortic implants). Indications, Safety, and Warnings - Mosaic and Mosaic Ultra - Medtronic Pre-6000 series Starr-Edwards valves were once considered contraindicated for MR imaging, but this prohibition has now been removed. For countries that use eIFUs, consult instructions for use at www.medtronic.com/manuals. Products Design is based on CT data from functional human tricuspid valves.
Surgeons performing middle ear surgery should have received specific training in the reconstruction and replacement of the middle ear ossicles prior to attempting implantation of Medtronic Xomed ossicular prostheses. As a precaution against implant extrusion through the tympanum, tissue grafts should be used as an interface between the implant and the tympanum.
MR Conditional, nonmetallic frame mitigates risk of corrosion betweensurgical valve and transcatheter valve stent materials.
Indications: The Medtronic Open Pivot Aortic Valved Graft (AVG) is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic valves, where a replacement valve and replacement or repair of the aorta is required. Medtronic Heart Valve Division Minneapolis, M. 3.0: Safe More.
Note: Manuals can be viewed using a current version of any major internet browser.
Download Brochure (opens new window) Product Details Undeniably Durable Less information (see less). Indications, Safety, & Warnings.
Indications: For the replacement of malfunctioning native or prosthetic aortic and/or mitral heart valves. For countries that use eIFUs, consult instructions for use at this websitemedtronic.com/manuals. Mosaic & Mosaic Ultra Bioprostheses The valve design allows blood to flow through the annulus encountering only tissue, not obstructive components such as the stent and sewing ring.
Hancock Pericardial .
View indications, safety, and warnings for the IndigoOtologic Drill. "MR Conditional" Carillon Mitral Contour Device in coronary sinus.
"MR Conditional" mitral annuloplasty device on chest x-ray.
Update my browser now. Note: Manuals can be viewed using a current version of any major internet browser.
Edwards MIRA aortic and mitral mechanical valves Models 3600, 3600f, 3600u, 9600 Edwards Lifesciences LLC www.edwards.com . Treatments & Therapies
Society for Medical Physics of the Netherlands (NVKF). We do not review or control the content on non-Medtronic sites, and we are not responsible for any business dealings or transactions you have there.
The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue-valve design expertise is an excellent choice for surgeons looking for long-lasting durability, exceptional performance and implantability for aortic, mitral, and MICS procedures. Healthcare Professionals
Various reports6-9have shown that the MB is a safe and well-performing device in the medium and intermediate terms. Indications: The Avalus bioprosthesis is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic valves. Instructions for Use.
If you continue, you may go to a site run by someone else. Accelerated structural deterioration due to calcific degeneration of bioprosthesis may occur in: children, adolescents, young adults, and patients with altered calcium metabolism (e.g., chronic renal failure, or hyperparathyroidism). Strength 3. Medtronic Neurosurgery Goleta, CA.
THE List - MRI Safety There is a risk of non sterile product and patient infection, in case any unutilized portions of product were to be re-used after first application. The Tri-Ad 2.0 Adams Tricuspid annuloplasty band repairs annular dilatation preserving 3D motion during the cardiac cycle, while providing free wall support and remodeling.
Roots arepressurized at 40 mm Hg with glutaraldehyde. Rie FC, Fradet G, Lavoie A, Legget M. Long-Term Outcomes of the Mosaic Bioprosthesis. Valve dimensions and geometry facilitate future ViV procedures. The implantation of oversized prosthetic valves can potentially result in the valve not functioning optimally.
Healthcare Professionals PMA Monthly approvals from 2/1/2022 to 2/28/2022 Original Total: 1 Supplements Total: 68 30-Day Notice P200030/S007 02/22/2022 X - 30-Day Notice GORE EXCLUDER CONFORMABLE AAA ENDOPROSTHESIS (CEXC). MeroGelOtologic Packing is a space-occupying dressing and/or stent intended to separate mucosal surfaces, help control minimal bleeding, and act as an adjunct to aid in the natural healing process.
There is a risk of non sterile product and patient infection, in case any unutilized portions of product were to be re-used after first application. Suitable for Future Interventions Valve dimensions and geometry enable future valve-in-valve (ViV) replacements. AccessGUDID - DEVICE: MOSAIC (00613994689061) More information (see more) Surgeons and cardiologists should continue to follow-up with their patients as per their usual practice and in accordance with published guidelines. MeroGel Otologic Packing is indicated for use in the middle ear and external ear canal following canalplasty, myringoplasty, tympanoplasty, and stapes and mastoid surgery. The following postoperative precautionary measures are recommended: Hydroxylapatite is the basic inorganic constituent of living bone tissue. Mechanical testing of human cardiac tissue: some implications for MRI safety, Translational and rotational forces on heart valve prostheses subjected ex vivo to a 4.7 T MR system, Assessment of magnetic field (4.7T) induced forces on prosthethic heart valves and annuloplasty rings, Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5T, State of the art of transcatheter mitral annuloplasty: present and future, Safety of magnetic resonance imaging in cardiac surgery patients: annuloplasty rings, septal occluders, and transcatheter valves (letter and response), 2020 ACC/AHA Guideline for the management of patients with valvular heart disease. The manufacturer is unwilling to provide an MR safety statement, so these must be considered "MR Unsafe." Artificial cardiac valves may be implanted by either an open surgical or transcatheter approach.
AHK 7700, Model 7700 heart valve Medtronic, www.medtronic.com. Update my browser now. Carpentier-Edwards annuloplasty rings, Models 4400 and 4500, marketed from 1980 to 1983, were made of stainless steel. Proprietary AOAanti-calcification tissue treatment that mitigates calcification and protects the tissue. The Contegra conduit offers a natural alternative for reconstruction or replacement of the natural right ventricular outflow tract (RVOT). With an updated browser, you will have a better Medtronic website experience.
Medtronic Xomed ossicular prostheses are indicated for the functional restoration of sound energy conduction in the middle ear as reconstructive devicesor artificial replacement for the natural ossicles of the middle ear.
Reconstruction or replacement of all or part of the ossicular chain may be necessary to correct structural damage of the middle ear ossiclesor conductive hearing loss resulting from a number of pathologic conditions, including but not limited to: Certain conditions may preclude the selection of ossicular prostheses implants as a means of restoring conductive hearing loss including: Surgery of the middle ear involves manipulation of fragile temporal bones and exposes inner ear structures to the risk of surgical trauma and infections.
For more information see the TGA Incident Reporting and Investigation Scheme (IRIS).
Corevalve Evolut PRO Bioprosthesis, Heart Valve Prosthesis.
Assists implantation with clear markings for proper orientation. Object Info: - MRI Safety The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue valve design expertise is an excellent choice for surgeons looking for long-lasting durability, exceptional performance, and implantability for aortic, mitral, and MICS procedures.
Your use of the other site is subject to the terms of use and privacy statement on that site.
Sensorineural deafness due to trauma during surgery, Post surgery displacement of the implant due to the development of scar tissue, To avoid postoperative vertigo and/or loss of inner ear functions, the surgeon should carefully assess the length of the implant in relation to the depth of the middle ear vestibule. Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician.
"MR Conditional" MitraClips attached to hold margins of mitral valve leaflets together.
Beute T, Goehler M, Parker J, et al. For countries that use eIFUs , consult instructions for use at this website www.medtronic.com/manuals. The SimuForm ring is elevating mitral repair its flexible anterior partaccommodates anterior motion, while the semi-rigid posterior part enables remodeling. It is possible that these complications could lead to: reoperation, explantation, permanent disability, heart failure, death. As reported in theMosaic bioprostheis Instructions for Use. Mosaic and Mosaic Ultra Bioprostheses. Medtronic Operational Headquarters 710 Medtronic Parkway Minneapolis, MN 55432-5640 USA, Central/Eastern Europe, Middle East & Africa, Electromagnetic Compatibility Guide for Cardiac Devices, Electromagnetic Compatibility for Cardiac Devices, California Transparency in Supply Chains Act, Information About Proposition 65 for California Customers, Digital Millennium Copyright Act (DMCA) Notification. The Mosaic bioprosthesis - based on more than 30 years of Medtronic tissue valve design expertise - is an excellent choice for surgeons looking for long-lasting durability, exceptional performance and implantability for aortic, mitral and MICS proced
1C.
Adverse events can include: cardiac dysrhythmias, death, endocarditis, hemolysis, hemorrhage, transvalvular or paravalvular leak, nonstructural dysfunction, structural deterioration, thromboembolism, valve thrombosis, or intracuspal hematoma. Reults, based on almost 10 years of clinical experience using dense hydroxylapatite in the middle ear, suggest that implants can be placed in direct contact with the tympanic membrane without the added risk of extrusion. Additional factors that may contribute to durability are: Our innovative Cinch implant system furthercapitalizes on the valves flexible stent to facilitatevalve implantation, particularly through a tightsinotubular space. For countries that use eIFUs, consult instructions for use at this website www.medtronic.com/manuals.
The Medtronic Open Pivot aortic valved graft unites a fundamentally different bileaflet heart valve design with leading graft technology for exceptional implantability.
MRI safety information | Edwards Lifesciences
AorTechAorticModel 3800TitaniumHeart ValveAortech Ltd.Strathclyde, U.K. AorTechMitralModel 4800titaniumheart valveAortech Ltd.Strathclyde, U.K. Aortic Mitroflow Synergy PCAortic Pericardial Heart ValveSize 19 mmSulzer Carbomedics, Inc., www.sorin.com, Aortic Mitroflow Synergy PCAortic Pericardial Heart ValveSize 29 mmSulzer Carbomedics, Inc., www.sorin.com, Aortic SJM Regent ValveMechanical Heart ValveSize 27 mm27AGN-751Rotatable AorticStandard Cuff-Polyester, AGNSt. Healthcare Professionals
After use, dispose according to applicable national practice. With an updated browser, you will have a better Medtronic website experience. The Medtronic Open Pivot aortic valved graft unites a fundamentally different bileaflet heart valve design with leading graft technology for exceptional implantability. Respiratory, Medtronic Operational Headquarters 710 Medtronic Parkway Minneapolis, MN 55432-5640 USA, Central/Eastern Europe, Middle East & Africa, Electromagnetic Compatibility Guide for Cardiac Devices, Electromagnetic Compatibility for Cardiac Devices, California Transparency in Supply Chains Act, Information About Proposition 65 for California Customers, Digital Millennium Copyright Act (DMCA) Notification. March 2018;105(3):763-769. Additional factors that may contribute to durability are: The benefits of AOA tissue treatment have been demonstrated through animal testing. 310C31: Medtronic Mosaic 310 Cinch Mitral Valve, 31mm
The Cinch implant system capitalizes on the flexible stent to facilitate valve implantation, particularly through tight patient anatomy: Handle (234 mm length) pliant, without locknut to be used with Mosaic or Mosaic Ultra prostheses, Handle (368 mm length) pliant, without locknut to be used with Mosaic or Mosaic Ultra prostheses, Mosaic mitral obturator set (no handles, no tray), LifeLine Cardiovascular
Hazard alert - potential for implanting oversized valves, Information for surgeons and cardiologists, TGA Incident Reporting and Investigation Scheme (IRIS).
The surgeon must fully assess the risks and benefits to the patient prior to the decision to implant ossicular prostheses. Edwards SAPIEN 3 Ultra transcatheter heart valve Even very old stainless steel valves are likewise considered of no danger in MRI.
Contraindications: The Medtronic Open Pivot Heart Valve is contraindicated in patients unable to tolerate anticoagulation therapy. All other bileaflet aortic valve anticoagulation should be managed at an INR of 2.0-3.0.
Can some patients with cardiac pacemakers undergo MRI. INDICATIONS, SAFETY, AND WARNINGS Mosaic and Mosaic Ultra Bioprostheses Indications for Use For the replacement of malfunctioning native or prosthetic aortic and/or mitral heart valves. The MRI examination must be performed using the following parameters: 1.5-Tesla or 3-Tesla, only Whole body averaged specific absorption rate (SAR) of 2-W/kg, operating in the Normal Operating Mode for the MR system Maximum imaging time, 15 minutes per pulse sequence (multiple sequences per patient are allowed)
Medtronic, Inc. 2018. A subset of these valves have required explantation within five years of implantation at an overall occurrence rate of 0.1% (one explant per 1000 aortic implants).
The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue-valve design expertise is an excellent choice for surgeons looking for long-lasting durability, exceptional performance and implantability for aortic, mitral, and MICS procedures. Warning: Persons allergic to cobalt-chromium .
Your use of the other site is subject to the terms of use and privacy statement on that site. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Medtronic Australasia is recalling the resources and will replace them with updated versions.
Nevertheless, the long-term effects of the Activent tube displaced into the middle ear are unknown. It is processed to render the tissue in the valve non-viable; it may be tissue only, or tissue attached to a metal or synthetic polymer framework. EpiDiscis contraindicated in patients with hypersensitivity to the product. Indications: For the replacement of malfunctioning native or prosthetic aortic valves with the option of aortic root replacement.
MeroGel is contraindicated in patients with hypersensitivity to the product. Healthcare Professionals Crown PRT Aortic Pericardial Heart Valve LivaNova, www.livanova.sorin.com. (such as Revo MRI, SynchroMed, Endeavor, Mosaic, Delta, InterStim) by Device Type (such as pacemaker, stent, otology implants, drug pump) Warning: Do not use magnetic resonance imaging (MRI) on a patient who has an implanted device until you review the following: All conditions for use for all implanted devices
Products The artificial valve incorporates synthetic materials and porcine heart valve tissue. Cardiovascular Diagram of "MR Conditional" mitral valve annuloplasty ring sutured into place. Products
To safeguard against postoperative sensorineural hearing loss, extreme care must be taken to avoid traumatizing the inner ear structures by unnecessarily contacting the inner ear structures with surgical instruments or the implant(s) or through the removal of perilymph from the vestibule.
With an updated browser, you will have a better Medtronic website experience. The Contour 3D remodeling ring is anatomically shaped. Mosaic Mitral Bioprosthesis Model 310 is not affected. Medtronic Australasia has updated both the iEOA Mosaic Aortic Bioprosthesis sizing chart and Mosaic obturators/sizers. Ann Thorac Surg. PMA Monthly approvals from 2/1/2022 to 2/28/2022 Original Total: 1 You just clicked a link to go to another website. The CG Future is an annuloplasty system for mitral valve repair, designed to predictably remodel the annulus to maintain apposition of the anterior and posterior leaflets.
Products
VALVE 310C31 MOSAIC MIT CINCH US Medical Device Identification The CG Future is an annuloplasty system for mitral valve repair, designed to predictably remodel the annulus to maintain apposition of the anterior and posterior leaflets.
Contraindications None known. View indications, safety, and warnings for the IPCSystem (lntegrated Power Console). You are strongly encouraged to talk with a health professional if you are concerned about a possible adverse event associated with a medical device.
Cardiovascular Be alert to the issue in your clinical decision-making and consider referring the patient to a relevant specialist, if required. Patients with an INR of 1.5-2.0 had a >60% reduction in bleeding events and no increase in TE compared to patients with an INR of 2.0-3.0.*. Update my browser now.
The artificial valve incorporates synthetic materials and porcine heart valve tissue. Mosaic and Mosaic Ultra Bioprostheses - Surgical Heart Valves - Medtronic This device has been approved as a humanitarian use device (HUD) in the United States. It is recommended that EpiFilm be used immediately after the opening of the pouch; discard any unused portion of the device. Physiologic Fixation, our advanced tissue fixation process, to mitigate biomechanical failures and promote long-term valve durability by: Improving preservation of valve structure and leaflet function, allowing it to function similar to a native valve.
THE List - MRI Safety After use, dispose according to applicable national practice.
Home First introduced in the 1980s, Hancock II is a second-generation valve with more than 25 years of clinical experience. Heart Valves and Annuloplasty Rings More. Caution: Federal Law restricts this device to sale by or on the order of a physician or properly licensed practitioner. Adverse events potentially associated with the use of prosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, hemolysis, hemolytic anemia, anticoagulant-related hemorrhage, myocardial infarction, leaflet entrapment (impingement), transvalvular regurgitation, structural dysfunction, pannus, perivalvular leak, transvalvular leak, thrombosis, stroke, thromboembolism.
Rie FC, Fradet G, Lavoie A, Legget M. Long-Term Outcomes of the Mosaic Bioprosthesis. The Simplici-T annuloplasty system offers a first-of-its-kind approach to mitral and tricuspid valve repair.
Medtronic.com Contact Medtronic Terms of Use Privacy Statement Patient Implant Information Previous Versions of Manuals 2023 Medtronic For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Mosaic 29 Surgical Heart Valve Repair and Replacement Orienting the bioprosthesis in the annulus such that the green suture marker is directed approximately toward the right fibrous trigone should position the widest intercommissural space appropriately. It is possible that these complications could lead to: reoperation, explantation, permanent disability, heart failure, death.